• 2.7V Snap In/Solder Terminal Supercapacitor

2.7V Snap In/Solder Terminal Supercapacitor

  • سلسلة: SSN
  • مجموعة العمل الجهد: 2.7Vdc
  • السعة المدى: 100F~400F
  • درجة حرارة العمل: -25~+70°C
  • تحميل الحياة: 500,000 cycles at 25°C
  • تطبيق: Consumer electronic, Portable power tools, DC-DC converters

  

دليل تحميل المنتج (ملفx) إرسال رسالة بريد إلكتروني لنا!

■ مقدمة المنتج

Snap In/Solder Terminal Supercapacitor 2.7V electrical double-layer capacitor

Feature:
High energy density, High power
Long cyclelife
Maintenance-free

Application:
● Electrictool, Consumer electronics
● Solar streetlight
● Energy recovery
● Main power, Back up power

■ Specification

Rated
Voltage
(V)
øDxL
(mm)
ESR
1kHz
ESR
(mΩ)
Maximum
Endurance
Current(A)
Maximum
Peak
Current(A)
Maximum
Leakage
Current
(72hrs/mA)
Power
Density
(W/kg
Maximum
Energy
(W.h)
Energy
Density
(Wh/kg)
Part number
 2.7V 100F  22x45  8  12  6.6  61.36  0.26  3391  0.1013  4.71  SSN2R7V107SS2245
 2.7V 120F  22x50  8  12  6.92  66.39  0.300  3170  0.1215  5.28  SSN2R7V127SS2250
 2.7V 120F  25x45  7  10  7.77  73.64  0.400  2734  0.1215  3.80  SSN2R7V127SS2545
 2.7V 150F  25x50  7  10  8.14  81.00  0.500  2499  0.1519  4.34  SSN2R7V157SS2550
 2.7V 200F  30x50  6  8  10.08  103.85  0.600  2457  0.2025  4.55  SSN2R7V207SS3050
 2.7V 220F  30x50  6  8  10.08  107.61  0.620  2430  0.2228  4.95  SSN2R7V227SS3050
 2.7V 250F  30x55  6  8  10.51  112.50  0.650  2377  0.2531  5.50  SSN2R7V257SS3055
 2.7V 360F  35x60  4  5  15.06  173.57  0.950  2536  0.3645  5.28  SSN2R7V367SS3560
 2.7V 360F  35x62  3  3.5  18.25  215.04  0.950  3267  0.3645  4.76  SSN2R7V367TW3562
 2.7V 400F  35x66  3  3.5  18.76  225.00  1.000  3302  0.4050  5.35  SSN2R7V407TW3566
 2.7V 400F  35x68  3  3.5  19.01  225.00  1.000  2941  0.4050  4.76  SSN2R7V407TW3568
 2.7V 400F  35x71  3  3.5  19.38  225.00  1.000  2890  0.4050  4.68  SSN2R7V407TW3571



Datasheet(PDF) of 2.7V Snap In/Solder Terminal Supercapacitor, please contact us.

■ How To Order
Send us the Part Number, for example, SRH2R7M506RS1840.


Handling Precautions and Guidelines:


For safety application, please contact us directly for any technical specifications, handling precautions and guidelines critical to application.
1.1 Precautions
(1) Prohibition of disassembly
    The disassembling may generate internal short circuit in the cell, which may cause gassing, leakage, explosion, or other problems.
    Electrolyte is harmful: In case the electrolyte come into contact with the skin, or eyes, physicians shall flush the electrolyte immediately with fresh  
    water and medical advice is to be sought. 
(2) Prohibition of dumping of cells into fire
      These may cause explosion of the cells, which is very dangerous and is prohibited.
(3) Prohibition of cells immersion into liquid
     The cells shall never be soaked with liquids such as water, seawater, drinks such as juices, coffee or others.
(4) Prohibition of use of damaged cells
      The cells might be damaged during shipping by shock. If any abnormal features of the cells are found such as damages in the cell package,      smelling of an electrolyte, an electrolyte leakage and others, the cells shall never be used any more.
       The Cells with a smell of the electrolyte or a leakage shall be placed away from fire to avoid firing or explosion

1.2 Handling Guidelines
(1) It is not suitable that cell is used under such conditions: AC circuit and wave filtering.
(2) Work voltage of cell should not exceed Max. work voltage of cell during using. Otherwise, will shorten shelf life,even cause swelling, leakage or crack.
(3) Please check the polarity before using. If working under reverse polarity, cell will not only shorten shelf life, but also heavy damage, such as swelling, electrolyte leakage etc.
(4) Environment
Work temperature will have an influence on shelf life of cell. As usual, higher work temperature will shorten shelf life. So, it is better that cell works under as possible as low environmental temperature.Work temperature of cell should consider internal work temperature in the unit and temperature rise when cellworks.
(5) IR drop
When main power sources shut down, cell will change into work mode from failure mode, at the same time, OCV will decrease due to IR drop. So please choose proper product type according to impedance specified in product datasheet and applied current.
(6) Cells in series connection
When cells in series connection for higher work voltage, it should be assured that work voltage of any single cell must not exceed Max. work voltage of single cell, otherwise, will shorten shelf life, even cause swelling, leakage or crack.
(7) Soldering
Heat shock will decrease electric performance of cell, even cause swelling, leakage or crack. Soldering temperature should not exceed 230℃, soldering time should not exceed 5s.
(8) Please don’t use reflow soldering of infrared heating and air heating.