48V 165F Super Capacitors Modules EDLC
Feature:
● High energy performance with low heat.
● generation and safe operation.
● Voltage balancing system.
● Temperature control
Application:
● Energy harvesting and supply, recovery systems for heavy duty and industrial applications (electric buses, trains,
cranes,alternative energy)
| ELECTRICAL PARAMETERS | ||
| Rated Voltage, Vr | 48 V | |
| Maximum Voltage | 52 V | |
| Rated Capacitance | 165 F | |
| Capacitance Tolerance | -0% + 20% | |
| Maximum ESR DC | Maxwell Technologies Test Procedure | 6.20 mOhm |
| Nesscap Co. Test Procedure | 5.5 mOhm | |
| Typical ESR DC | Maxwell Technologies Test Procedure | 4.80 mOhm |
| Nesscap Co. Test Procedure | 3.10 mOhm | |
| Test Current for Capacitance and ESRDC | 100 A | |
| Maximum Peak Current, 1 second (non repetitive) | 1950 A | |
| Leakage Current, maximum (passive voltage balancing system) | 6.0 mA | |
| POWER AND ENERGY | ||
| Specific Energy, Emax | 3.9 Wh/kg | |
| Stored Enerqy | 53 Wh | |
| Usable Specific Power, Pd |
Maxwell Technologies Test Procedure | 3.3 kW/kg |
| Nesscap Co. Test Procedure | 3.7 kW/kg | |
| Maximum Specific Power (matched impedance), Pmax |
Maxwell Technologies Test Procedure | 6.9 kW/kg |
| Nesscap Co. Test Procedure | 7.8 kW/kg | |
| TEMPERATURE | ||
| Operating Temperature (ambient temperature) | -40°C ~ +65°C | |
| Storage Temperature (stored discharged) | -40°C ~ +70°C | |
| LIFE TEST | ||
| ESR Change (% increase from maximum initial value) | 100% | |
| Capacitance Change (% decrease from minimum initial value) | 20% | |
| LIFE | ||
| High Temperature (at Rated Voltage and Maximum Operating Temperature) |
1500 hours | |
| Room Temperature (projected life at Rated Voltage and 25°C) | 10 years | |
| Cycle Life (Rated Voltage - Half Voltage, Test Current - 100A, at 25°C) | 1000000 cycles | |
| Shelf Life (stored discharged up to a Maximum Storage Temperature) | 4 years | |
| SAFETY | ||
| Short Circuit Current, typical (maximum current if shorted at Rated Voltage. Do not use as an operating current) |
7750 A | |
| Highpot Test | 2500 V | |
| BALANCING SYSTEM / TEMPERATURE CONTROL | ||
| Internal Temperature Sensor | NTC Thermistor | |
| Temperature Interface | Analog | |
| Cell Voltage Monitoring | Overvoltage Alarm | |
| Connector | Deutsch DTM | |
| Cell Voltage Management | Passive Voltage Balancing System | |
| PHYSICAL PARAMETERS | ||
| Power Terminals | M8/M10 | |
| Recommended Torque - Terminals | 20/30 Nm | |
| Cooling | Natural Air Convection | |
| Mass | 13.5 kg | |
| EDLC DIMENSIONS AND PHYSICAL PARAMETERS | ||
| L mm | W mm | H mm |
| 412 | 212 | 171.4 |