• 16V 500F Super Capacitors Modules EDLC

16V 500F Super Capacitors Modules EDLC

  • Series: EDLC
  • Working Voltage Range: 16V
  • Capacitance Range: 500F
  • Working Temperature: -40~+65°C
  • Load Life: 1,000,000Cycles
  • Application: Energy harvesting and recovery systems for heavy duty applications,Wind turbine pitch control,UPS systems,Micro Grid

  (※Click this button to inquiry)

Download Product Manual (PDF file) Send an E-mail to us!

■ Product's Introduction

16V 500F Super Capacitors Modules EDLC

Feature:
High energy performance with low heat.
● generation and safe operation.
● Active voltage balancing system.
● Temperature control

Application:
● Energy harvesting and recovery systems for heavy duty applications
● Wind turbine pitch control
● UPS systems
● Micro Grid

■ Specification
 ELECTRICAL PARAMETERS
 Rated Voltage, Vr  16 V
 Maximum Voltage  18V
 Rated Capacitance  500 F
 Capacitance Tolerance  -0% + 20%
 Maximum ESR DC  Maxwell Technologies Test Procedure  2.10 mOhm
 Nesscap Co. Test Procedure  1.80 mOhm
 Typical ESR DC  Maxwell Technologies Test Procedure  1.60 mOhm
 Nesscap Co. Test Procedure  1.00 mOhm
 Test Current for Capacitance and ESRDC  100 A
 Maximum Peak Current, 1 second (non repetitive)  1950 A
 Leakage Current, maximum  (passive voltage balancing system)  6.0 mA

 POWER AND ENERGY
 Specific Energy, Emax   3.3 Wh/kg
 Stored Enerqy   17.8 Wh
 Usable Specific Power,
 Pd
 Maxwell Technologies Test Procedure  2.8 kW/kg
 Nesscap Co. Test Procedure  3.3 kW/kg
 Maximum Specific Power
 (matched impedance), 
 Pmax
 Maxwell Technologies Test Procedure  5.9 kW/kg
 Nesscap Co. Test Procedure  6.8 kW/kg

 TEMPERATURE
 Operating Temperature (ambient temperature)  -40°C ~ +65°C
 Storage Temperature (stored discharged)  -40°C ~ +70°C

 LIFE TEST
 ESR Change (% increase from maximum initial value)  100%
 Capacitance Change (% decrease from minimum initial value)  20%

 LIFE
 High Temperature (at Rated Voltage and Maximum Operating
 Temperature)
 1500 hours
 Room Temperature (projected life at Rated Voltage and 25°C)  10 years
 Cycle Life (Rated Voltage - Half Voltage, Test Current - 100A, at 25°C)  1000000 cycles
 Shelf Life (stored discharged up to a Maximum Storage Temperature)  4 years

  SAFETY
 Short Circuit Current, typical
 (maximum current if shorted at Rated Voltage.
 Do not use as an operating current)
 10000 A
 Highpot Test  2500 V

 BALANCING SYSTEM / TEMPERATURE CONTROL
 Internal Temperature Sensor  NTC Thermistor
 Temperature Interface  Analog
 Cell Voltage Monitoring  Overvoltage Alarm
 Connector  SAL-8-FK3-0,2
 Adapter  SAL-8-FK3 to Deutsch DTM04-4P
 Cell Voltage Management  Active Voltage Balancing System

 PHYSICAL PARAMETERS
 Power Terminals  M8/M10
 Recommended Torque - Terminals  20/30 Nm
 Cooling  Natural Air Convection
 Mass  5.2 kg

EDLC DIMENSIONS AND PHYSICAL PARAMETERS
                L mm                                 W mm                             H mm
                  414                                    63                               184

Datasheet(PDF) of 500F 16V, please contact us.

■ How To Order
Send us the Part Number, for example, MXEDLC-0500E016.

Click to search products

INQUIRY

Send your message to us. We'll respond as soon as possible.

E-mail will not be published (required)
Name (optional)
Tel (optional)
Company (optional)
Address (optional)
点击刷新验证码

Message (required)